![]() The character typed should be displayed on the monitor. Then, jumper (using a wire, paperclip or car key, etc.) pins 2 and 3 of the serial cable together while pressing any character on the PC’s keyboard. Verify the cable is pinned as a straight-thru serial cable (pin 2 to 2, pin 3 to 3 and pin 5 to 5) and not as a null-modem or other pin-out configuration.ĭisconnect the serial cable from SecureSync. ![]() Using a multimeter, ring out the pins from one end of the serial cable to the other. If the terminal emulator program does not display any data when the keyboard key is pressed, either SecureSync is not powered up or there is a problem with the connection between SecureSync and the PC. The port settings of the terminal emulator should be configured as 115200, N, 8, 1 (flow control setting does not matter). Communication with this port is via a standard DB9 F to DB9M serial cable (minimum pinout is pin 2 to 2, pin 3 to 3 and pin 5 to 5) connected to a PC running a terminal emulator program such as Tera Term or Microsoft HyperTerminal. The serial port is a standard DB9 female port. The front panel or rear panel serial port can be used for SecureSync configuration or to obtain select data.